    Green environmental protection, high temperature resistance, no discoloration at 300 ℃, no combustion at 400 ℃, low temperature resistance - 30 ℃ - 70 ℃, no decomposition

    technical parameter

    ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??

    Surface resistance

    106-109Ω

    Volume resistance

    105-108Ω

    hardness

    70-75

    Wear rate

    < 0.02g/cm2

    Dispersion time

    < 0.1s


    Common specifications
    ? ??

    ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?

    surface treatment

    亞光Dull/光面(亮光)glossy/防滑Anti slip/花紋Pattern

    Dimension (L x W)

    10mx1.2m、10mx1.0m、10mx0.9m
    ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 10mx0.8m、10mx0.7m、10mx0.6m

    colour

    Green / black, blue / black, gray / Black


    Yellow / black, black / black, white / Black


    thickness

    1.0mm,2.0mm,3.0mm,4.0mm,5.0mm



    Friendly reminder:


    ? ?
    ? ? ? ? ? ? ? ? ? ? ? ?
    ? ? ? ? ? ? ? ? ? ? ??

    It can be customized according to customer requirements (length, width, thickness, color, etc.).

    The company's anti-static rubber plate (table mat and floor mat) adopts pure high-quality rubber. We promise that it will never contain secondary rubber, waste rubber, recycled rubber and plastic. You can cut and proofing for free.

    The product has passed the SGS test, meets the ROHS standard, and the halogen meets the standard.



    Application of antistatic rubber plate

    ? ?

    Static conductive and anti-static rubber plate (table mat and floor mat) is applicable to aerospace, national defense, coal mine, black powder, pyrotechnic, electric initiating explosive products, ammunition charging assembly, civil blasting equipment, fireworks and firecrackers, electronic components, electronic instruments and meters, liquefied petroleum gas tank station, electronic semi conductor devices, electronic computers Electrostatic conductive rubber plate, anti-static rubber plate floor and worktable are paved in the production workshop and warehouse of electronic communication equipment, integrated circuit microelectronics industry and other industries in order to eliminate the accumulation of static electricity in human body and environment and prevent static hazards and accidents.


    The function of paving static conductive and anti-static rubber plate (table mat, floor mat) ground and worktable is to effectively leak the static electricity on human body, tooling, equipment and materials into the ground and eliminate the static electricity harm to human body and environment. Prevent fire and explosion accidents caused by electrostatic discharge in the production site of flammable and explosive products; Prevent breakdown damage of components and finished components caused by electrostatic discharge in the production site of electronic products; Relieve the electrostatic shock and mental burden caused by electrostatic discharge.



    Laying of anti-static rubber plate

    ? ?There are two laying methods of static conductive and anti-static rubber plates (table mat and floor mat), floating laying and pasting. Floating paving is to directly lay 2-5mm thick rubber plate on the ground, which is flexible and simple, but the gap at the joint of rubber plate is easy to accumulate dust. Pasting is to paste the 2-5mm thick rubber plate on the ground with electrostatic conductive rubber liquid. The gap at the joint of rubber plate can be 1.2x1000x10000mm thin rubber plate, cut into 30-50mm wide rubber strips with a paper cutter, brush and paste the electrostatic conductive rubber liquid on the gap surface at the joint of rubber plate. The straight edge of 5mm thick rubber plate can also be cut into positive and negative slopes with a paper cutter (or special cutter), roughened slightly, and coated with electrostatic conductive rubber solution for lap bonding.

    Requirements for base course ground

    ? ? Wooden floors, asphalt floors, floors of buildings on the second floor and above belong to insulated floors. Copper sheets must be pasted on the ground before paving rubber plates. Copper sheets are generally made of thin copper strip profiles. Copper sheets are pasted on the ground into a rectangular grid intersecting horizontally and vertically. The size and quantity of copper sheet pasting spacing can be determined according to the needs of their respective production workshops and warehouses, Fix the attached copper strip and reliably connect it with the electrostatic grounding branch line (or trunk line) to provide electrostatic leakage channel. Non insulated floors such as cement floor and terrazzo floor on the first floor can be paved directly on the ground without installing copper sheets.

    Precautions for sticking rubber plate to the ground

    1. The ground and rubber plate shall be free of dust, oil stain and moisture, and must be clean and dry;

    2. Before pasting, clean the pasted surface with 120 ° gasoline, dry it, and then apply rubber liquid;

    3. The ambient temperature shall be 25 ° c-42 ° C, and the relative humidity shall not be higher than 60%, which is generally good;

    4. The adhesive surface of rubber plate shall be roughened slightly with coarse sand wheel, coarse sand paper, wood file, etc. (the edge of 30-50mm adhesive surface must be roughened);

    5. The rubber liquid must be brushed twice on the pasted ground and rubber plate surface with a brush. The first time is dried for 20-30 minutes, and the second time is dried until it is slightly sticky;

    6. If the rubber solution is too thick and inconvenient for construction, toluene can be added in the proportion of 10-20% of the rubber solution, diluted and stirred evenly before use

    7. After the rubber plate is pasted on the ground, it shall be rolled with a round roller weighing more than 5kg for more than 5 times;

    8. Pay attention to ventilation and fire prevention during construction;

    9. During the use of rubber plate floor, if it is found that it is dehydrated and crimped due to mechanical operation, the above pasting method can be used for subsidy and repair.



    Resistance measurement of anti-static rubber plate ground


    The measuring instrument is an insulation resistance tester, with DC open circuit voltage of 500V and short-circuit current of 5mA. The measuring electrode is made of copper or stainless steel into a cylindrical standard electrode with a diameter of 60 ± 2mm and a weight of 2 ± 0.2kg. The measuring electrode must be treated against oxidation.

    1. Place two measuring electrodes 1m apart on the ground, connect the two wiring terminals of the instrument with the electrodes respectively, and measure the resistance between the electrodes;

    2. Place a measuring electrode on the ground, connect one terminal of the instrument with the electrode, and connect the other terminal to the grounding network of the workshop and warehouse (if there is no grounding network, it can be connected to the water filled tap water pipe), and measure the resistance to ground at this point;

    3. At least 5 measuring points shall be selected for each workshop and warehouse. The measuring points shall be selected at the place where production workers operate and often walk, and shall be 1m away from the grounding body;

    4. The arithmetic mean value shall be taken for both the inter electrode resistance value and the polar resistance value;

    5. The ground resistance of electrostatic conductive rubber plate is ≤ 5x104 Ω or 5x104-106 Ω; The ground resistance value of anti-static rubber plate shall be in the range of 106 Ω - 109 Ω.


    常見問題1 2 3
    你可能還喜歡
    • Green smooth floor mat YY-A1002

      Green smooth floor mat YY-A1002

    • Blue smooth floor mat YY-A1002

      Blue smooth floor mat YY-A1002

    • Gray smooth floor mat YY-A1002

      Gray smooth floor mat YY-A1002

    Anti static experts have focused on the R & D and production of anti-static products for 29 years
    Scan QR code for more information
    National hotline:
    Tel: 0576-87071888
    0576-87071889
    Mobile: 136 6168 8095
    mail box:
    zxl@zjyiyuan.cn
    zj@zjyiyuan.com

    本站使用百度智能門戶搭建 管理登錄
    主站蜘蛛池模板: 欧美激情乱人伦| 欧美jizz18性欧美年轻| 日产精品一致六区搬运| 亚洲五月激情综合图片区| 激情内射亚洲一区二区三区| 和主人玩露出调教暴露羞耻| 韩国日本好看电影免费看| 国产精品v欧美精品v日韩精品| A国产一区二区免费入口| 性色欲网站人妻丰满中文久久不卡 | 在线播放真实国产乱子伦| 一边摸一边爽一边叫床免费视频| 日本换爱交换乱理伦片| 乱子伦一级在线观看高清| 欧美日韩亚洲成人| 亚洲视频在线观看视频| 精品三级66在线播放| 啊轻点灬大ji巴太粗小说太男 | 老湿机香蕉久久久久久| 国产大片线上免费看| 亚洲最大激情中文字幕| 国产精品高清2021在线| 99在线热视频只有精品免费| 妖精的尾巴ova| 两个小姨子韩国电影| 搞黄网站免费看| 久久久受www免费人成| 日韩欧美国产高清在线观看| 亚洲丝袜制服欧美另类| 欧美成人亚洲欧美成人| 亚洲永久精品ww47| 澳门a毛片免费观看| 免费a级毛片在线播放| 精品亚洲aⅴ在线观看| 又大又黄又粗又爽的免费视频| 色老头成人免费视频天天综合| 国产又爽又色在线观看| 鲁啊鲁啊鲁在线视频播放| 国产成人免费a在线资源| 国产精品h在线观看| 国产激情一区二区三区四区|